4. Programming
82 496791
Partition Programming
Introduction
When programming the 9851 there are two ways of changing the control unit
from a single system to a partitioned system: a) during initial power up or b)
by using Command 98.
To create a partitioned system during initial power up see page 28.
If you have an existing 9851 that has already been programmed as a single
system, and wish to convert it to a partitioned system, then:
1. Enter programming mode (if you are not already there).
2. Key in 98 at the keypad.
The display shows:
3. Press 1 at the keypad.
The display shows (for example):
4. Either: Press 1 to create a partitioned system
Or 0 to create a single system.
The display shows (for example):
5. Press .
The keypad gives a double confirmation tone and the system loads the
factory default Command values, erasing all previously programmed
values.
Notes:The log is protected and cannot be erased by the Installer.
Partition Programming
Once you have changed a 9851 into a partitioned system then you can use
the following Commands to program each partition:
1. Use Commands 01 to 16 and 17 to 40 to assign each zone to a
Partition.
Each zone defaults to Partition A.
Use 5 to assign zones to Partition B.
Use 6 to assign zones to Partition C.
Use 8 to assign zones to Partition D.
2. Use Command 32 to assign each keypad to a Partition as required. By
default all keypads belong to all Partitions.
3. Program the exit mode, alarm response, entry time and exit time for
each Partition as follows: