4. Programming
496791 59
If you select option 0 the control unit will report supervision failure as de-
scribed for Command 128.
Number of Digits in Access Codes (Command 56)
The control unit can use either four-digit or six-digit access codes. To select
four digit access codes choose option 0. Select option 1 for six digit access
codes.
Note: Changing from four- to six-digit access codes (or from six- to four-digit access
codes) causes the system to revert to factory defaults for all access codes. Six
digit user code default is 123456 and Engineer code default is 567890.
Battery Load Test (Command 57)
Use this Command to make the control unit regularly test its backup battery.
Option 0 The control unit does not load test the battery at all.
Option 1 The control unit tests the battery when the system is unset or 23
hours after the last battery test (whichever comes first).
If the battery fails a test then the control unit reports to the central station.
The control unit also gives a regular short tone from the keypad sounders,
and the keypad shows the message “Batt Load Fail”.
Day Tamper Indication (Command 58)
Use this Command if you want the Engineer to reset tamper indications that
occur while the system is unset.
Option 0 The user can reset a displayed tamper while the system is unset.
Note: Use Command 38 to allow the user to reset the system after
a tamper alarm.
Option 1 The Engineer must reset a displayed tamper while the system is
unset. Note that the user can continue to set and unset the system
while a tamper is being displayed.
Sounder Tamper (Command 59)
The control unit can connect to external sounders with one of two tamper
arrangements:
Option 0 The external sounder uses negative voltage tamper return.
Option 1 The tamper return to the external sounder is terminated with a 2k2
resistance.
Select the appropriate option for the sounder fitted to the system.
Level B Final Exit Operation (Command 60)
Command 60 controls how the system will treat Final Exit zones in part set
Level B. (This Command does not affect Partition B in a Partitioned system.)
When the Command option is set to 0 any Final Exit zones included in part
Comentarios a estos manuales