4. Programming
80 496791
Note: 1. If the control unit is using Fast Format signalling, and has sent a Burg to the
ARC, then the control unit activates the output pin assigned to Comms Ac-
knowledge when the ARC returns a Comms Acknowledge signal. (Use Com-
mand 101 to enable comms.)
2. The control unit delays reporting/loging either mains loss, or exiting engi-
neering with mains loss, by 15-18 min (chosen randomly). If you chose a
Scandinavian default in Command 0 then the control unit waits at least 60
minutes before reporting.
Confirmation Timer (Command 160)
Note: Enable Alarm Confirmation (Command 89) to access this Command.
This Command controls a timer. The timer starts when an alarm is triggered
for the first time. If a second alarm is triggered before the timer expires then
the control unit transmits a confirmed alarm to the ARC. You can set the
timer to any value in minutes between 1 and 999. For DD243: 2002 compli-
ance set confirmation time to default (=30 mins).
Internal Sounder (Command 161)
Note: Enable Alarm Confirmation (Command 89) to access this Command.
This Command selects whether the control unit will operate the internal
sounder for a confirmed alarm of for an unconfirmed alarm.
Option 0 The control unit operates the internal sounder for an unconfirmed
alarm.
Option 1 The control unit operates the internal sounder for a confirmed
alarm.
External Sounder (Command 162)
Note: Enable Alarm Confirmation (Command 89) to access this Command.
This Command selects whether the control unit will operate the external
sounder for a confirmed alarm of for an unconfirmed alarm.
Option 0 The control unit operates the external sounder for an unconfirmed
alarm.
Option 1 The control unit operates the external sounder for a confirmed
alarm.
Confirmation After Entry (Command 163)
Note: Enable Alarm Confirmation (Command 89) to access this Command.
This Commands controls how the system treats alarms that arise during
entry. The options select the number of non-entry route zones that must be
triggered to provide a confirmed alarm during the entry time.