4. Programming
54 496791
With option 1 selected the system communicates tamper events to the ARC
and starts the internal sounder. When unset, the system also communicates
“RF Low Battery” for any radio detectors that have low batteries and either
causes an alarm or sends supervision signals.
Note: Do not select option 1 if you have two or more 24 hour zones.
With option 0 selected the system starts the internal sounder only.
System Tamper Reset (Command 38)
This Command allows you to choose whether the customer can reset the
system after a tamper alarm. This facility is independent of that offered by
Commands 31 and 33. If you select option 0 (customer) then the user can
reset the system after a system tamper alarm providing no fault exists. If you
select option 1 (engineer) then you must enter the engineer access code at a
keypad to reset the system after a system tamper alarm.
Level A Exit Mode (Command 39)
Use this Command to select the exit mode for Full Set or Partition A.
Option 0 Timed. Use this option EITHER if the user completes setting the
system by pushing an exit terminate button connected to a keypad
OR if no exit terminate button is connected, and the system sets
after a delay selected using Command 44.
Option 1 Terminate. Use this option if the user completes setting the
system by pushing an exit terminate button connected to a key-
pad. Note that the exit time is infinite in this option.
Option 2 Final door set. Use this option to complete setting the system by
closing a door fitted with a Final Exit zone detector. Note that the
exit time is infinite in this option.
Option 3 Single system: Lock Set (see below).
Partitioned System: Instant Set. Use this option to make the
system set without delay or exit tone.
Option 4 Silent Set (This option is not available on a single system.) The
system gives the exit time programmed in Command 44 but
without exit tones. When the system sets the keypad gives a
double beep.
Option 5 Lock Set. (Partitioned system.) To use this method you must
install a lock switch with the contacts connected to the ET termi-
nals of a keypad. This facility is available on keypad software
version 1.4.2 onwards.
Note: Do not assign the keypad to more than one Partition. Do not
connect more than one lockswitch (or any other device) to the