496791 25
3. Installation
The terminals on the 9851 control unit main pcbs are described as Safety
Extra-Low Voltage circuits (SELV), according to the definitions in Safety
Standard EN60 950.
The terminals on the built in communicator are described as SELV or Tel-
ecommunications Network Voltage (TNV) according to the definitions in
Safety Standard EN60 950.
Note: The labels "SELV" and "TNV" which are shown in Figure 19 are for reference
only and do not appear on the 9851 main pcb.
It is important that the installer ensures that TNV terminals are connected
ONLY to the PSTN or other circuits designated as TNV circuits. SELV
terminals must be connected ONLY to other circuits designated as SELV
circuits. Strict adherence to the installation instructions will ensure that the
equipment continues to comply with safety regulations to which it was ap-
proved.
Connecting the Telephone Line
Direct connection, or interconnection via other apparatus, to the terminals on
the internal communicator can produce hazardous conditions on the tel-
ephone network. Always seek advice from a competent telephone engineer if
in any doubt regarding connection to these terminals.
The person responsible for connection of the internal communicator to a
PABX system must be as follows:
a) If the wiring is owned by British Telecom PLC, British Telecom must
connect the wiring to the communicator.
b) If the wiring is not owned by British Telecom, either:
(i) British Telecom
(ii) The authorised maintainer
(iii) A professional Installer after 14 days written notice to the author-
ised maintainer.
Connect the telephone line as follows:
If the telephone line is already terminated with a suitable lead and plug then
insert the plug into the RJ11 connector (see Figure 19).
Otherwise (see Figure 20):
1. Using a three core cable (type 1/05mm CW1308), strip back 5mm of
two cores and feed through one of the cable entries in the rear of the
9851 casing. Connect the two cores to the terminals, A and B on the
9851 PCB.
2. Connect the cable from the A and B terminals on the 9851 PCB to the
corresponding terminals on the BT master box.
Comentarios a estos manuales