Cooper Security 9853 Guía de instalación Pagina 27

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 102
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 26
496791 21
3. Installation
OP3
TR
ST
LS
TR
ST
LS
+ve 12V Aux
Shock Sensor Reset
Use Command 83 4
VIPER
+ve
0V
OP3
TR
ST
LS
TR
ST
LS
+ve 12V Aux
+ve 12V Aux
French Siren Test
Use Command 83 X1
(for use in France only)
SIREN
+ve
0V
OP3
+ve 12V Aux
Bell Follow Buzzer/Relay
Use Command 83 0
Relay energises/buzzer sounds
when bell activates.
BUZZER/RELAY
OP3
PIR Set Latch/Walk Test
For:
Set Latch use Command 83 3
Walk Test use Command 83 5
PIR
Figure 17. Wiring Examples for Programmable Output OP3
Wiring Keyswitches
Figure 18 shows the connections for a 9928 Keyswitch Interface.
Note: You can fit only one keyswitch interface per system
M/C
M/C
M/C
0V
12V
CLK
DATA
ET
PA
SET
RDY
9928
COM
KS2
KS1
Set A
Off
Set B
Set A
Set B
TAMP
Momentary
Continuous
To keypad bus
on control unit.
Figure 18. Connecting a 9928 Keyswitch Interface
Vista de pagina 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 101 102

Comentarios a estos manuales

Sin comentarios