4. Programming
76 496791
In addition, if you have used Command 121 to program channel 3 with Fast
Format communications then the control unit will add a 20 second delay
before dialling an alarm call.
To disable Communication Acknowledge use option 0.
Report Restorals (Command 123)
This option is only available if you have selected Scancom Fast format in
Command 103.
Restore off (0) The system does not communicate restorals.
Restore on (1) Enabled. The system will communicate restorals.
Reverse Open/Closed (Command 124)
Note: This Command is normally used in France.
This option is only available if you have selected Scancom Fast format. With
this option enabled the Open/Close Fast Format channel is reversed as
follows:
Option disabled Option enabled
On setting system False True
On unsetting system True False
Note: This option does not afffect the separate Open channel and Close channel.
No Closing Signal if More Than One Circuit Omitted
(Command 125)
Note: This Command is required for Belgian BVVO approval.
This option is only available if you have selected Scancom Fast format.
When this option is enabled the control unit will NOT transmit a Close signal
if a user has omitted two or more zones.
Select Language (Command 126)
The control unit can display messages on the keypads in one of several
different languages. Use Command 126 to select the language you wish to
use. The options available are:
Option 0: English (default) Option 5: French
Option 1: Italian Option 6: German
Option 2: Spanish Option 7: Norwegian
Option 3: Portuguese Option 8: Swedish
Option 4: Dutch Option 9: Danish
Radio Zone Supervision Fail Response (Command 128)
If the system is fitted with a 9955 Radio Expander then all the radio zones are
supervised. Should a radio zone not communicate with the 9955 expander
for one hour or more then the 9955 reports a supervision failure to the control
Comentarios a estos manuales