4. Programming
70 496791
Static Test Call (Command 105)
In static testing the system makes a test call either at one particular time of
day or on one day every month.
To make calls at a set time every day press A and then key in a number
between 01 and 24 to select the time of day for the call. For example, key 18
to program the control unit to make a static test call at 6:00pm every day.
To make calls one day every month press B and then key in the day number
of of the call. The day number should be between 1 and 24. The control unit
will make a test call at 1am on the selected day.
Note that the control unit will add or subtract up to 16 minutes at random to
the time you specified. This is to make sure that the ARC is not overwhelmed
with a flood of test calls from systems that have all been given the same time.
Key in 00 to disable static test calls.
Line Fail Response (Command 106)
This Command lets you program the system to respond with either audible or
silent alarms when the system detects a fault on an attached telephone line.
The exact response depends on whether the system is set or unset, as
follows:
Disabled (0) The control unit does not monitor the telephone line.
Audible (1) If the system is unset then the system logs the event. The
keypad produces a short audible tone every minute.
Entering a valid access code silences the sounders and
the keypads indicate a telephone line fault. The system
can be set again with the line fault present.
Note: Audible response is the NACOSS recommendation for line fault.
If the system is set then the control unit logs the event but
the keypads do not give any tone or display. The control
unit cancels any programmed bell delay if the line is out of
order when an alarm occurs.
Silent (2) If the system is unset then the keypads indicate a tel-
ephone line fault and the control unit logs the event. The
system may be set again with the line fault present.
If the system is set then the keypad does not give any
indication or tone but the control unit does log the event.
The system cancels any programmed bell delay if the line
is out of order when an alarm occurs.