Engineer Menu 1-6 Engineering Manual
76
Option 1-6: Defining the Setting Mode
Exit For Ward>2
Timed Exit
Exit For Ward 2
> Timed Exit
[
1234567890123456
1234567890123456
Eng 1 Menu 6
Setting Modes
Exit For Ward 2
> Instant Set
Exit For Ward>1
Timed Exit
[
|
|
e.g.
e.g.
To select the war d, press
or to scroll
Ward number (only
those wards allocated
to zones are available)
1. SELECTWARD
2. SELECT THE
SETTING MODE
4. EDIT TIMERVALUE
[
Press to save changes and continue[
To select the setting mod e:
Press or
to scroll, or
Press the mode hot key
This option determines the events that must take place before the panel arms the selected
ward. Each ward can have a different setting.
)
The setting specified in option 1-8-2 (page81) is used when wards are set via a ward group.
1 – Final Exit
Select this option if you want the ward to set once the user has chosen to set the ward
and activated a Final Exit zone (page 23). The panel sets the ward after the number of
seconds specified by the Exit Settle time (page 63).
2 – Exit Terminate
Select this option if you want the ward to set once the user has chosen to set the ward
and activated an Exit Terminator zone (page 23). The panel sets the ward after the number
of seconds specified by the Exit Settle time (page 63).
3 – Timed Exit
Once the user has chosen to set the ward, this option causes the ward to set after the
number of seconds specified by the Exit time (page 60).
The Exit Settle time (page 63) is included within the Exit time. Therefore, if the Exit time is,
for example, 30 seconds and the Exit Settle time is10 seconds, the Exit Settle period starts
20 seconds into the Exit period. The minimum period that the panel can set the ward is
after 10 seconds (this would be used if, for example, you set the Exit time to zero).
Activation of an Exit Terminator zone (if used) can shorten the period for the ward to set.
For example, if the Exit Terminator zone is triggered 5 seconds into the Exit period, and
the Exit Settle time is 7 seconds, the zone is set 12 seconds after the user has chosen to
set the ward.