Engineer Menu 1-1 Engineering Manual
28
Confirmation On.
After Entry Yes.
Confirm 2 zones.
Step 3 – Select Attributes
Each zone can have one or more of the following attributes to alter its operation.
1– Access
Normal Alm zones programmed with this attribute are automatically isolated during the
entry or exit procedure to allow a "walk through" route to access the keypad or to exit.
The Entry zone type (page 24) performs the same function.
You may also want to apply this attribute to a Final Exit zone type to prevent the "zone in
fault triggered" tone when exiting.
2 – Double Knock
Zones programmed with this attribute will cause an alarm only if the zone is triggered a
specified number of times within the Double Knock period (page 63), or the zone remains
active for the whole of the Double Knock period.
The number of times the zone needs to be triggered is determined by the Double Knocks
counter (page 65).
3 – Soak Test
This attribute is useful if you want to place a zone under test. The attribute enables you to
find out whether activations of the zone have occurred, without the activations causing
alarms.
After setting the attribute, the zone is isolated for the period specified by the Soak Test
timer (page 63). If the zone is activated during this period, the activation is logged,
outputs of type Soak Test Fail (page 45) are triggered and the user is informed of the zone
failure after entering a user code. The test fail message is cleared only after entering the
Engineer's code.
If at the end of the test period no activations have occurred, the control unit removes the
attribute from the zone.
Note: The control unit resets the soak test time to zero whenever an engineer or installer
logs in or applies power to the control unit.
4– Omittable
Zones with this attribute can be omitted from the setting procedure by using User option
1-2 (see the
Manager's Manual
). If the Automatic Omits configuration option is selected
(page 85), zones that are active when the system is set are automatically omitted.
5 – Reset
This attribute is normally assigned to a zone that is connected to a vibration or smoke
detector. The zone is not monitored for approximately 12 seconds during the exit
procedure. This allows the sensor to stabilise, and prevents false alarms.
Vista de pagina 35
1 2 ... 31 32 33 34 35 36 37 38 39 40 41 ... 179 180

Comentarios a estos manuales

Sin comentarios

Ss-cycle Top Dead Center Locator Handbücher

Bedienungsanleitungen und Benutzerhandbücher für Für Motorräder Ss-cycle Top Dead Center Locator.
Wir stellen 1 PDF-Handbücher Ss-cycle Top Dead Center Locator zum kostenlosen herunterladen nach Dokumenttypen zur Verfügung Bedienungsanleitung






Weitere Produkte und Handbücher für Für Motorräder Ss-cycle

Modelle Dokumententyp
Sprocket Shaft Bearing and Seal Installation Tool Bedienungsanleitung   S&S Cycle Sprocket Shaft Bearing and Seal Installation Tool User Manual, 4 Seiten
Manifold/Engine Measuring Tools Bedienungsanleitung   S&S Cycle Manifold/Engine Measuring Tools User Manual, 4 Seiten
Degree Wheel Kit PN 53-0020 Bedienungsanleitung   S&S Cycle Degree Wheel Kit PN 53-0020 User Manual, 4 Seiten
Rocker Cover Wrench Set Bedienungsanleitung   S&S Cycle Rocker Cover Wrench Set User Manual, 2 Seiten
Balancing Kit Bedienungsanleitung   S&S Cycle Balancing Kit User Manual, 9 Seiten
SPO Quiet Baffle (PN 55-6023) Bedienungsanleitung   S&S Cycle SPO Quiet Baffle (PN 55-6023) User Manual, 4 Seiten
Engine Shipping Crate Box Assembly 50-9581 Bedienungsanleitung   S&S Cycle Engine Shipping Crate Box Assembly 50-9581 User Manual, 4 Seiten
Packing Harley-Davidson Twin Cam 88B Engine in S&a Bedienungsanleitung   S&S Cycle Packing Harley-Davidson Twin Cam 88B Engine in S&S Shipping Crate 50-9589 User Manual, 2 Seiten
Packing Harley-Davidson Twin Cam 88 Engine in S&am Bedienungsanleitung   S&S Cycle Packing Harley-Davidson Twin Cam 88 Engine in S&S Shipping Crate 50-9587 User Manual, 2 Seiten
49-State EPA Certified Engine Bedienungsanleitung   S&S Cycle 49-State EPA Certified Engine User Manual, 8 Seiten
Engine Shipping Crate 50-9578 Bedienungsanleitung   S&S Cycle Engine Shipping Crate 50-9578 User Manual, 4 Seiten
California X-Wedge Engine Bedienungsanleitung   S&S Cycle California X-Wedge Engine User Manual, 8 Seiten
California V-Series Engine Bedienungsanleitung   S&S Cycle California V-Series Engine User Manual, 8 Seiten
Ignition System For All 1999–03 Carbureted Harley- Bedienungsanleitung   S&S Cycle Ignition System For All 1999–03 Carbureted Harley-Davidson Twin Cam 88 Engines User Manual, 14 Seiten
Replacing Data Link Connector Plug Used In SSW+ Ig Bedienungsanleitung   S&S Cycle Replacing Data Link Connector Plug Used In SSW+ Ignition Kit 55-1050 User Manual, 1 Seiten
IST Ignition System for S&S V-Series Engines w Bedienungsanleitung   S&S Cycle IST Ignition System for S&S V-Series Engines with Flywheel Machined for Crank Trigger User Manual, 14 Seiten
IST Ignition System for 1984-1999 Big Twin and Cus Bedienungsanleitung   S&S Cycle IST Ignition System for 1984-1999 Big Twin and Custom Applications User Manual, 17 Seiten
Single-Fire Ignition Coil Bedienungsanleitung   S&S Cycle Single-Fire Ignition Coil User Manual, 1 Seiten
Super Stock Ignition Bedienungsanleitung   S&S Cycle Super Stock Ignition User Manual, 8 Seiten
Cycle Guardian Diagnostic System Bedienungsanleitung   S&S Cycle Cycle Guardian Diagnostic System User Manual, 16 Seiten