Engineer Quick Reference Engineering Manual
162
If following a ward:
00= Bell-SAB 25= Exit
01= Strobe 26= Exit/Ent.
02= Switch 12 27= Exit Flt
03= Det.Reset 28= Sndr Ctl.
04= Walk Test 29= Perimeter
05= Alarm 30= Shunted
06= P.A Alarm 31= AlwaysOff
07= Fire Alm. 32= SetStrobe
08= Set 33= Access
09= 2nd Entry 34= LS Open
10= 24Hr Alm. 35= PSU Batt
11= Cnf Alarm 36= PSU Fuse
12= Zone Omit 37= PSU Mains
13= Act.Omit 38= Mask Tamp
14= 24Hr Omit 39= Mask Flt
15=Set Fail 40= Mask Alarm
16=Settling 41= Security
17=Clear 42= Supervision Fail
18=Tamper 43= RF Jammed
19=Reset Req 44= Tx Lo Batt
20=Lock-Out 45= Telcmd Batt
21=Chime On 46= Set Pulse
22= Monitor 47= Unset Pulse
23= Alm Abort 48= Fault 4k4
24= Entry 49= Ready Set
If following a zone:
1= Mimic 4= Test Fail
2= Alarm 5= Omit
3= Tamper
1-5 Timers
p60
1-5-1: Ward Timers
1= Exit 3= Bell Delay
2= Entry 4= Bell Duration
p60
1-5-2: System Timers
01= Confirmation 17= Service Time
02= Sys Bell Dly 18= Select Menu
03= Sys Bell Dur 19= Keys Til Tamp
04= Anti Mask 20= No. of Rearms
05= Line Fault 21= Remote Resets
06= AC Off Delay 22= Double Knocks
07= Soak Test 23= Tst Call Strt
08= Exit Settle 24= Test Call Int
09= 2nd Entry Dly 25= Reset Alg.
10= Double Knock. 26= Payment Time
11= Abort Period 27= Hi Security
12= Abort Delay 28= Supervision Warning
13= Courtesy Time 29= Supervision Fail
14= Menu time-Out 30= Set Status
15= Beam Pair 31= Defer Count
16= Defer Setting 32= A.Set Warning
p62
1-5-3: Exceptions
p66
1-5-4: Auto-Sets
p70
1-5-5: Time Switches
p72
1-5-6: Code Locks
p75
1-6 Setting Modes
1= Final Exit 4= Instant Set
2= Exit Terminate 5= Deferred Set
3= Timed Exit 6= Lock Set
p76
1-7 Custom Text
1= Reset message 5= Banner Text
2= Location text 6= Group Names
3= Printer title
4= Remote Reset Msg
p78
1-8 Group Options
p80
1-8-1: Assign Groups
Group 1 to 4 (8 on M2000)
p80
1-8-2: Exit Modes
1= Final Exit 5= Deferred Set
2= Exit Terminate 6= Lock Set
3= Timed Exit 7= Silent Set
4= Instant Set
p81
1-8-3: Group Timers
1= Exit 3= Bell Delay
2= Entry 4= Bell Duration
p82
1-8-4: Alarm Response
1= Full 3= Internal
2= Local
p83
1-9 Configuration
p84
1-9-1: General
01 = Ward OFF / ON
02 = Bell is an SAB / Bell is an SCB
03 = View Alms Unset / View Alms P.set
04 = Engr Authorised / User Authorised
05 = On-Line (Keypad) Enabled / Disabled
06 = Unset Ward First / Set Ward First
07 = Digi Normal / Digi Inverted
08 = Chime Audible /Chime Visible
09 = Manual Omits / Automatic Omits
10 = Omit Tampers No / Omit Tampers Yes
11 = Global Setting / Local Setting
12 = Global Unsetting / Local Unsetting
13 = 24hr Omit Global / 24hr Omit Local
14 = Ward Bell Time / Global Bell Time
15 = Latching Fire / Nonlatching Fire
16 = Timed code o/p / Latched code o/p
17 = Latching 24hr / Nonlatching 24hr
18 = Access code only / Access all codes
19 = NVM is Unlocked / NVM is Locked
20 = Unshunt, no exit / Unshunt & exit
21 = Ignore errors / View exit errors
22 = Mimic, All times / Mimic, Set only
23= Lo Security Eng. / Hi Security Eng.
24= Duress Allow NO / YES
25= Keypad PA OFF/ON
26= P.Set Hotkey YES/NO
27 = Exit Foyer / Inst Set Foyer
28 = Unset Entry Wards / All Wards.
29 = Radio PA Audible / Silent
30 = Silent Alerts / Audible Alerts
31 = Bus cut Conf / Unconf
p84
1-9-2: DD243
01 = Confirmation On / Off
02= Sndrs on Unconf / Confirm
03= Bells on Unconf / Confirm
04= After Entry No / Yes
05= Ent KPD Lock Off / On
p89