Engineering Manual Engineer Menu 1-4
55
16 – Settling
Activates when the Exit Settle timer (page 63) is running for the selected ward.
17 – Clear
Activates when the selected ward has no tamper conditions and no zones activated. The
output deactivates when the selected ward has a tamper or zone activation.
18 – Tamper
Activates when any type of tamper condition is triggered in the selected ward; deactivates
when all tamper conditions have been reset in the ward. This output acts as a "global"
tamper indication for any type of tamper associated with the ward.
19 – Reset Req
Activates when the selected ward requires an engineer or remote reset; deactivates when
the ward has been reset either by the engineer or by a remote reset.
20 – Lock-Out
Activates when a security key (page 27) has locked out keypads in the selected ward;
deactivates when the Security zone type is no longer active.
21 – Chime On
Activates when any zone in the selected ward causes a chime tone, as determined by the
Chime Tone attribute (page 29).
22 – Monitor
If the output is latched, the output activates when a zone that has the Monitored attribute
(page 30) and is in the selected ward activates, and deactivates when the zone deactivates.
If the output is pulsed, it activates when a zone that has the Monitored attribute and is in
the selected ward activates, and remains active for the pulse duration.
23 – Alm Abort
Activates after an alarm in the selected ward has been aborted by the user; deactivates
when the Abort Period timer (page 63) has expired, or when the alarm is reset (whichever
occurs first).
24 – Entry
Activates when the Entry Delay timer (page 61) is running for the selected ward;
deactivates when the selected ward is unset or when the Entry Delay timer expires.
25 – Exit
Activates when the selected ward starts the exit procedure; deactivates when the selected
ward is set.
26 – Exit/Ent.
Activates when the selected ward is in entry or exit mode.