159
Appendix C: Compliance Guide
This appendix explains how to configure M-Series control units to fulfil the requirements of
DD243: 2004, the ACPO PA Reduction Policy and PD 6662 / prEN 50131-1: 2004.
DD243: 2004 Compliance
Please study this section if both of the following apply:
1. You are installing an alarm system in the United Kingdom.
2. The system has remote signalling and requires the local Police Authority to issue a URN
(Unique Reference Number).
)
Note: The installed system will fully comply with the requirements of DD243: 2004 only if it
has been designed in accordance with this section.
To comply with paragraphs 6.4.2 to 6.4.6 of DD243: 2004, select the following options.
DD243: 2002 Para: 6.4.2 6.4.3 6.4.4 6.4.5 6.4.6
Possible Installation Unset from
outside using
a keyswitch
zone input
Exit Mode of
"Lock Set"
Keypad and
User access
code
Portable ancillary
control equipment
(with reader inside
premises)
Requires ARC
to unset
Option
E1-9-2-01 Confirmation
On/Off
On On On On On
E1-3-2-01 Confirmed
Reset
Either Either Engineer (or
Remote Reset)
Engineer (or Remote
Reset)
Either
E1-3-2-02 Unconfirmed
Reset
Either Either Either Either Either
E1-5-2-01 Confirmation
Time
30 – 60 mins 30 – 60 mins 30 – 60 mins 30 – 60 mins 30 – 60 mins
E1-9-2-04 After Entry No No No Yes No
E1-9-2-05 Entry Keypad
Lock
Off Off Off On Off
E1-9-2-06 Confirm n
zones
N/A N/A N/A 2 Zones N/A
N/A = Not applicable
Options E1-9-2-02 and E1-9-2-03, which select whether sounders and bells start on the
confirmed or unconfirmed alarms, may be configured as preferred but "unconfirmed" is
recommended.
Communication signalling options are required to indicate to the ARC whether the system is set
or unset and when a confirmed alarm occurs. This can be achieved using SIA or Contact ID, or
using one of the following optional output types (E1-4) with "Digi H/Wired" or "Digi On Board":
008 – System Set 009 – System Full Set 011 – Confirmed
Vista de pagina 166
1 2 ... 162 163 164 165 166 167 168 169 170 171 172 ... 179 180

Comentarios a estos manuales

Sin comentarios