161
Engineer Quick Reference
Engineer Menu 1
1-1 Program Zones
Zone type:
0= Not Used Shunt Key
1= Normal Alm Tamper
2= 24 Hour Perimeter
3= PA Silent Lock Set
4= PA Audible PSU Battery
5= Fire PSU Fuse
6= Technical PSU Power
7= Final Exit Masking
8= Exit Term Occupancy
9= Entry Security
Keyswitch Shock Entry
Attributes (toggle to change to YES/NO):
1= Access Chime Tone 3
2= Double Knock Inverted
3= Soak Test Shuntable
4= Omittable Beam Pair
5= Reset Monitored
6= Masking Non Latching
7= Entry Supervision
8= Chime Tone 1 Activity
9= Chime Tone 2
p20
1-2 Zones Advanced
Zone resistance:
1= 4K7/2K2(CC) 3= 4K7/4K7
2= 1K0/1K0 4= 2K2/2K2
Zone Output Group
p32
1-3 Ward Options
p34
1-3-1: Equipment to Wards
p34
1-3-2: Attributes
01= Conf Reset 09= Re-arms
02= Unconf Reset 10= Secure Ward
03= Tamper Reset 11= Bell & Strobe
04= Remote Reset 12= Foyer Mode
05= Panel Tamper 13= Unset Fire
06= Panel Speaker 14= Multiply Ack
07= Aux/ Bell Tamp 15= Entry Unset
08= Payment Timer 16= Entry=F/E
p35
1-4 Outputs
Output type:
1= Panel 4= Equipment
2= Digi H/Wired 5= O/M Modules
3= Digi On Board 6= Custom Outputs
Follows:
1= System 4= User
2= Ward 5= Zone Output Group
3= Zone
If following the system:
000= Bell (SAB) 059=PSU - Power
p39
001= System Strobe 060=General Fault
002= Switch 12 Volts 061=Mask Tamper
003= Detector.Reset 062=Mask Fault
004= Walk Test 063=Mask Alarm
005= Alarm 064=Fault 4k4
006= Panic Alarm (PA) 065=Pending
007= Fire Alarm 066=Always off
008= System Set 067=Ext. Line Fault
009=System Full Set 068=ATS Test
010=System Open 069=Ready to set
011=Confirmed 070=Auxiliary Fuse
012=Courtesy Light 071=Bell Fuse
013=Engineer On Site 072=Network 1 Fuse
014=Active Omit 073=Network 2 Fuse
015=Zones Omitted 074-079=Always Off
016=24 Hour Omitted 080=Rem Batt Fault
017=24 Hour Alarm 081=Rem Mains Off
018=Zones Shunted 082=Rem Pwr Out Flt
019=Technical 083=Sys Batt Fault
020=PSTN Line Fault 084=Sys Mains Fault
021=Panel Mains Off 085-099=Always Off
022=Access Code 100=Auto-Setting
023=Soak Test Fail 101=Always Off
024=First Knock 102=Always Off
025=Digi Failed 103=Always Off
026=Digi Successful 104-108=Always Off
027=Digi Active 109=PC Output 1 On
028=2nd Entry Only 110=PC Output 2 On
029=Entry Only 111=PC Output 3 On
030=Exit Only 112=PC Output 4 On
031=Exit / Entry 113-118=Always Off
032=Exit Fault 119=Custom O/P 1 On
033=Tamper Alarm 120=Custom O/P 2 On
034=Rem Service Call 121=Custom O/P 3 On
035=Code Accepted 122=Custom O/P 4 On
036=Service Required 123=Custom O/P 5 On
037=Reset Required 124=Custom O/P 6 On
038=Strobe On Set 125=Custom O/P 7 On
039=Duress Alarm 126=Custom O/P 8 On
040=System Part Set 127-128=Always Off
041=LockSet Unlocked 129=Time Switch 1 On
042=Set Failed 130=Time Switch 2 On
043=Shunt Code 131=Time Switch 3 On
044=Random Output On 132=Time Switch 4 On
045=Modem Lockout 133=Time Switch 5 On
046=Aux/Bell Tamper 134=Time Switch 6 On
047=Panel Lid Tamper 135=Time Switch 7 On
048=Chime Mimic 136=Time Switch 8 On
049=Monitored O/P On 137=Time Switch 9 On
050=Alarm Abort 138=Time Switch 10 On
051=Rem Call Enabled 139-148=Always Off
052=Relearn Required 149= Supervision Fail
053=Always On 150= RF Jammed
054=Always Off 151= TX Low Battery
055=Battery Test On 152= Tcmd Low Batt
056=Panel Battery Fault 153= Set Pulse
057=PSU - Battery 154= Unset Pulse
058=PSU - Fuse
Comentarios a estos manuales