Engineer Menu 1-3 Engineering Manual
38
15 – Entry Unset
Use this option to specify which wards must first have their entry timer running, or be in
alarm, before being unset, or which wards can be unset directly from a telecommand. If a
ward appears in this list then a user must start the entry timer for the ward (for example by
opening a Final Exit door). By default all wards appear in the list. If a ward does not appear
in the list then a user can unset the ward directly from the telecommand. (See also Option
1-9-1-28.)
16 - Entry = F/E
This causes any zones programmed as type Entry (page 24) to be regarded as a Final Exit
zone type when the ward is set. For example, if ward 2 is selected in the Entry=F/E, when a
user sets ward 2 any Entry zone type in that ward will be immediately considered as a Final
Exit zone type.
Typically, this option is used in domestic applications for a hall PIR that is used for two
wards, e.g. ward 1 (set when leaving the building) and ward 2 (set when going to bed). If
ward 2 (but not ward 1) is included in Entry=F/E, the hall zone is used as a Final Exit zone
type when setting ward 2.
Note Zones programmed as Normal Alm with the Access attribute (page 28) will remain as
walk through zones and are not affected by this option.