Engineering Manual Getting Started
17
MSNode. NODES include MIDNodes, IDNodes and TS
Nodes.
If the number of devices detected is not as expected,
check the connections to the devices and their address
settings (normally set by a link on the device's PCB).
7. Press [ until you see the following:
Equipment
Confirmed
8. Press ]. After a few seconds the display shows:
Engineer Level 1
Press [ENT] or [2]
You are now logged on as an engineer and are ready
to configure the system.
About Logging in as an Engineer
Logging in as an engineer causes other keypads connected directly to the same network or
MSNode to display "System Busy". Keypads connected to a different network or MSNode
display ”Engineer on Site", and other engineers or users can log on to these.
You set the factory default engineer code when starting the control unit for the first time (see
page 16) and selecting the default security Grade. For Grade 2 the factory default engineer code
is 1234. For Grade 3 the factory default engineer code is 123400. In addition, you can change
the system between four digit or six digit access codes (see page 91). If the system is set up for
6-digit codes, the default is 123400.
You will not be able to log in as an engineer if:
Another engineer or user is currently logged in at the keypad that you using.
A user has fully set the system (i.e. all wards armed).
Note that you are able to log in if the system was set by an engineer or is partially set (i.e.
not all wards armed). This latter case enables you to log in if, for example, the site has
safes or other "strong" areas that are often armed throughout the day.
A user has prevented you from gaining access using User option 1-9.
The Hi Security Eng configuration option is selected (page 88) and you do not have a "remote
reset" code.
Logging Out
If you want to log out (i.e. exit from the Engineer menus completely), keep pressing ] until you
see the following, then press [.
Press [Ent] To
Leave Menus