Cooper Security M2000 Guía de usuario Pagina 42

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 180
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 41
Engineer Menu 1-3 Engineering Manual
34
Option 1-3: Assigning Ward Equipment and Attributes
Option 1-3-1: Assigning Equipment to Wards
Ward Options 1
Equip To Wards
1,01 Remote
Ward : 12345678
1,02 Remote
Ward : 12345678
1,02 Remote
Ward > 1234....
1,02 Remote
Ward > 123*....
e.g.
Note:
Ward Options - Attributes
See ne xt section for
Devic e typ e
Netwo rk 1, De vic e 01
Sho ws wa rd s tha t d e vic e is
in (initially shows all wards)
Eng 1 Menu 3
Ward Options
[
[
[
[
|
e.g.
1. SELECT "EQUIP TO
WARDS" O PTI O N
Pre ss wa rd n u m b e r
18
to to togg le
device in ward (ward number shown) or not
in wa rd ("* " d isp la ye d ).
Pre ss t o sa ve c ha n g e s a nd c o nt inu e
[
Netwo rk 1, De vic e 02
To select network device:
Pr e s s o r
to scroll, or
Enter zone num ber (e.g. 102)
By default, the device is
in a ll wa rd s t ha t its zo ne s
have been allocated to
in Engineer menu 1,1. A
dot (".") indicates that
none of the device's
zo n e s a re in th e wa rd
2 . SEL EC T DEVICE
3. SELECT WARDS
Use the Equip To Wards option to assign each keypad, MSNode, MSPSU, MIDNode/IDNode,
MRNode and LEC2 to the appropriate wards. For the device type, choose Remote for a keypad,
MSNode for an MSNode, RNode for an MRNode, or Node for an MIDNode/IDNode, LEC2.
It is important to allocate each device to the correct wards, since this will ensure correct
responses from the system. For example:
If a tamper alarm occurs at a keypad, and the keypad is assigned to ward "n", then internal
sounders operate (and the control unit communicates a “tamper” fault) if ward "n" is unset.
If ward "n" is set, the alarm response is determined by option 1-8-4 (page 83).
If a “Standard Ward” user code is assigned to ward "n" (user option 2-4), the user code will
only be able to set and unset ward "n" from a keypad that is assigned to ward "n".
)
The control panel tamper, extension loudspeaker and external bell tamper can be assigned
to wards using the Panel Tamper, Panel Speaker and Bell Tamp attributes (page 36).
)
The bell and strobe can be assigned to wards using the Bell & Strobe attribute (page 37).
)
Keypads and loudspeakers connected to an MSNode or MSPSU are automatically allocated
to the same wards as the Node. The loudspeaker and keypad sounder follow the wards
assigned to the Node. For example, if an MSNode is assigned to wards 2 and 3, the
loudspeaker and keypad sounder will operate when ward 2 or3 requires an entry, exit or
Vista de pagina 41
1 2 ... 37 38 39 40 41 42 43 44 45 46 47 ... 179 180

Comentarios a estos manuales

Sin comentarios