Engineering Manual Engineer Menu 1-9
95
User Reset – A user can reset a supervision failure by entering their access code at a
keypad.
Engineer or Remote Reset – The engineer must reset a supervision failure by entering their
access code at a keypad, or remotely.
17 – Reset Jamming Engineer/User
Always – The control unit clears a jamming alert if the MRNode detects that the jamming
has stopped.
User Reset – A user can reset a jamming alert by entering their access code at a keypad.
Engineer or Remote Reset – The engineer must reset a jamming alert by entering their
access code at a keypad, or remotely.
18 – Battery Fault Alert Reset
Auto – The control unit clears the alert when it detects that the panel battery is healthy.
User – The control unit clears the alert when an end user enters their code, provided the
panel’s battery is healthy.
Engineer – The control unit clears the alert when either the engineer enters their code at
the keypad, or performs a remote reset, provided the panel’s battery is healthy.
19 – Battery Low Alert Override When Setting
This option decides whether the user can carry on setting the system when there is an
alert caused by a battery fault at the control unit or a remote power supply.
Never – The control unit will not allow users to set the system from a keypad.
Healthy – If there has been an alert, but the batteries are all healthy at the time the user
tries to set the system from the keypad then the control unit asks the user if they wish to
proceed. The user can abort setting or carry on. If the user carries on with setting then the
control unit logs a “set with battery fault” event.
If the batteries are not healthy when the user tries to set the system, then the control unit
will not allow the system to set.
Always – If the user tries to set the system from the keypad, then the control unit will ask
the user if they wish to proceed. The user can continue setting or abort. If the user
continues setting then the control unit logs a “set with battery fault” event.
20 – Status Display
This option decides whether or not the keypads shows the system set status.
Never – The keypads show the set/unset status only after a user has entered their access
code. The control unit removes the status information as soon as the control unit finishes
setting a ward.
Timed – The keypads display the set/unset status of the system for a programmed number
of seconds after the control unit has finished setting a ward. To program the length of
time that setting status is visible use Option 1 - 5 - 2: - 30 (see page 66).
Always – The keypad always shows the set/unset status of the system.