Text Keys Engineering Manual
156
The keypad connected to Network 1 follows the panel speaker. Therefore the panel speaker
must be assigned to ward(s) used by that keypad. Keypads connected to MSNodes on
Network 2 will follow the MSNodes’ ward assignment.
Eng 1 Menu 5 - Timers
E1-5-1 Ward Timers
Ward Exit Entry Delay (Bell) Duration (Bell)
1 30 (default) 45 0 (default) 15 (default)
2 30 (default) 20 0 (default) 15 (default)
3 30 (default) 20 0 (default) 15 (default)
Eng 1 Menu 6 – Setting Modes
Ward Mode (Hot Key)
1 Final Exit (1)
2 Final Exit (1)
3 Final Exit (1)
User programming
User 2 Menu 4 – Edit Codes
User Code Type Wards Auto Sets Auto Un-sets
01 5678 Master 123 123 123
02 2222 Standard Ward 2 2 2
03 3333 Standard Ward 3 3 3
04 4444 Standard Global 23 23 23
05 5555 Standard Ward 23 23 23
A User with a “Standard Ward” code can set the wards which have been assigned to the
keypad were the code is entered. If the User has been assigned more than one ward, then
only the ward assigned to the keypad will set.
A User with a “Standard Global” code can set all wards assigned to that User from any Keypad.
The “remote” wards will follow “Instant Set” mode as there is no one present in that area to
activate the “Final Door”.
A Master user mimics the functions of a “Standard Global” code.
Digital Communicator
The onboard communicator can be programmed to meet the requirements of ATS2. This is
therefore suitable for a PD6662:2004 Grade 2 installation.
The communicator must be connected to a PSTN phone line.