Appendix - Profile
On initial power-up, or after defaulting the system, the
control unit offers you the choice of loading a profile. The
profile supplies the following values in the Installer Menu.
If you do not select the profile then the control unit
makes all zones “not used” with names “zone 01” to
“zone 16” and makes all outputs “not used” with names
“output 1” to “output 4”.
Zones
Name Type Part
Set
Chime Force
Set
Zone 1 "Front door" Final Exit Yes Yes No
Zone 2 "Back door" Final Exit Yes Yes No
Zone 3 "Hall" Entry Route Yes No No
Zone 4 "Living room" Normal Alarm Yes No No
Zone 5 "Dining room" Normal Alarm Yes No No
Zone 6 "Kitchen" Normal Alarm Yes No No
Zone 7 "Landing" Normal Alarm No No No
Zone 8 "Garage" Normal Alarm Yes Yes No
Zone 9 "Fire" Fire No No No
Zone 10 "Zone 10" Normal Alarm No No No
Zone 11 "Zone 11" Normal Alarm No No No
Zone 12 "Zone 12" Normal Alarm No No No
Zone 13 "Zone 13" Normal Alarm No No No
Zone 14 "Zone 14" Normal Alarm No No No
Zone 15 "Zone 15" Normal Alarm No No No
Zone 16 "Zone 16" Normal Alarm No No No
Outputs
Name Type
Output 1 "Siren" Siren
Output 2 "Strobe" Strobe and set
Output 3 "Output 03" Not used
Output 4 "Output 04" Not used
Other
Full set A name "Full set" Remote needs entry Disabled
Part set B name "Part set" Auto rearm Never
Exit mode Timed set Siren time 15 minutes
Exit time 40 seconds Supervision Enabled
Entry time 40 seconds Jamming Enabled
Part Set Exit mode Instant set Silence Alerts User Code
Part set, Final Exit = Final Exit Installer code 7890
Part set, Entry Route = Final Exit
Panic Alarm keys No User 1 to 16 name "User 01" to
"User 16"
Quick set Yes User 1 code 1234
User Code required Yes User 2 to 16 code None