i-on16 Programming
Page 43
The Installer code allows you to enter the Installer Menu,
and carry out an Installer reset. However, the Installer
code does not allow you to set or unset the system.
Installer Text
If required the installer can key in a text message that
appears on the first line of the display in the standby
screen. This could be, for example, the name of the
installer’s company. See page 31 for a description of how
to enter text.
Remote needs Entry
Instead of using an entry timer triggered by a Final Exit
zone to allow the user to gain access to the control unit
and unset the system, the user can employ a remote
control. To chose between either of these options select:
System Options – Remote needs Entry. The options available
are:
Enabled: The user must first trigger an entry zone and
start the entry timer before unsetting the system.
Disabled: The user can unset the system using a
remote control without first starting the entry timer.
Auto Rearm
To change the number of times that the system will re-
arm when the siren time expires select: System Options-
Auto Rearm.
Select NEVER to make the system never re-arm (the
system will go into alarm once only). Select one of the
other options to make the system re-arm once, twice,
three, four or five times, or always. The system re-arms
all closed zones, but not detectors that are still sending
alarm signals.
If the system has rearmed, then when a user enters the
system through the entry route the control unit will give
an audible internal alarm in place of the normal entry
tone.