Programming i-on16
Page 44
Siren Time
To change the length of time that the system operates
the siren during an alarm select System Options-Siren Time.
Note: The durations offered by the display apply to a
siren wired directly to the control unit.
The 760ES radio siren has one of three fixed sounder
durations in an alarm: 5seconds, 3mins or 15mins.
These fixed durations are designed to preserve the
battery life of the radio siren.
Supervision
If a detector loses contact for more than two hours then
the control unit raises an alarm. The options available for
this alarm are:
Option: With system SET,
the control unit:
With system UNSET
the control unit:
Disabled Does nothing. Does nothing.
Fault Logs the event (but
does NOT display any
alert or fault tone).
Displays an Alert and
sounds a fault tone and
logs the event.
Jamming
The control unit can detect interfering (or "jamming")
radio signals. To enable jamming detection select System
Options - Jamming.
If the control unit detects jamming once you have
enabled this option then the display shows an Alert
message for the user.
Force Set
You may wish to allow a user with a remote control to set
the alarm system when one or more of the detectors are
not working or are open (active).
Note: If you enable “Force Set” then the system does not
comply with EN50131.