i-on16 Programming
Page 47
control unit ends the call and then re-attempts to
connect up to a maximum of 15 times.
Alternate.
The control unit reports to one of the two telephone
numbers in the Phone Book.
Operation: The control unit dials the first telephone
number and attempts to connect to the ARC. If it
fails, it will then close down and dial the second
telephone number and attempt to connect to the
ARC. If received and acknowledged on this attempt,
the alarm transmission is complete. If the control unit
fails to connect to the second telephone number, it
will close down again and re-attempt to connect to
the first telephone number. The control unit will
continue to shuttle between the two numbers up to
15 times.
Phone Book
Use this menu to store two telephone numbers that the
control unit uses to report alarms to the ARC. The control
unit accepts one telephone number if you choose Single
in the Call Mode menu, or two telephone numbers if you
select Alternate call mode.
The control unit can store telephone numbers up to 31
digits long.
Use the u and n keys to move the cursor backwards and
forwards through the number if you wish to edit it.
Press
< to delete the digit to left of the cursor.
Press * to add a 2 second pause, if required. The display
shows this as a comma.
Account Number.
To store an ARC account number select Reporting – Alarms
– Account Number.
With CID the system reports alarms using a four digit
account code.
With Fast Format you can use four-, five- or six-digit
codes. The control unit pads five-digit codes to six digits
using a leading zero. The control unit leaves four- and
six-digit codes unchanged.