Installation i-on16
Page 22
ABCEA1B1
Se e N o t e
PSTN
WARNING: Telecommunications Network Voltage
A, B Connect to PSTN
A1, B1 Connect to local phone extension (if required)
E For added surge protection connect to a suitable protective earth.
C Note: (UK only) connect to ringing wire from PSTN and to ringing wire on
extension phone, if fitted.
Figure 20. Telephone Connection
Note: The microphone for recording speech messages is
on the I-SD01 module, as well as a small speaker
that allows you to playback the messages.
If you intend to record speech messages, and the
user’s keypad is already fixed at some distance from
the central station, you may wish to temporarily
connect a second keypad to the end station. This will
enable you to program the system and easily
record/playback any speech messages.
Alternatively, you can enable the end station tamper
switch to act as a start/stop/playback recording
button. See page 54 for details.
Removing an I-SD01
If you wish to remove an I-SD01 from a system then
make sure that you first
disable calls in both the Reporting
– Alarms – Call mode menu (see page 46 ) and in the
Reporting – Speech Dialler – Call mode menu (see page 53 ).
If you do not do this then the end station will continually
report a PSTN line fault.