4. Programming
496792 61
Level C Entry Time (Command 74)
This Command sets the entry time for Level C. See “Programming Com-
mands” for options.
Level C Exit Time (Command 75)
This Command sets the exit time for Level C. See “Programming Com-
mands” for options.
Level D Exit Mode (Command 76 (9752 only))
Command 76 specifies the exit mode for Level D.
Option 0 The keypad sounders and any internal sounders give a low tone
when entering Part Set Level D. Use Command 79 to select the
exit time.
Option 1 Instant Set (no exit tone)
Option 2 Silent Set. Use Command 79 to program the Exit time. At the end
of the exit time the keypad gives a double beep confirmation tone.
Option 3 Lock Set. See “Level A Exit Mode (Command 39) for an explana-
tion of Lock Set.
Option 4 Level D exit mode is the same as Level A. The system gives full
volume setting tones.
Level D Alarm Response (Command 77 (9752 only))
Command 77 specifies the alarm response for Part Set Level D.
Option 0 Keypad sounders only.
Option 1 Internal sounders and keypad sounders.
Option 2 Local alarm (internal and external sounder only).
Option 3 Full alarm (communication and internal/external sounders).
Level D Entry Time (Command 78 (9752 only))
This Command sets the entry time for Level D. See “Programming Com-
mands” for options.
Level D Exit Time (Command 79 (9752 only))
This Command sets the exit time for Level D. See “Programming Com-
mands” for options.
Output Programming (Commands 81, 82 and 83)
The system has three transistorised, high current, programmable outputs.
Command 81 programs output 1, Command 82 programs output 2 and
Command 83 programms output 3. All three Commands take a single follow-
ing digit that selects the function.
Note: The outputs are a "pull down” type that provide negative applied control
signals. The outputs are +12V when inactive, and 0V when active.