4. Programming
60 496792
Level B Exit Time (Command 65)
This Command sets the exit time for Level B. See “Programming Com-
mands” for options.
Level C Final Exit Operation (Command 70)
Command 70 controls how the system will treat Final Exit zones in Part Set
Level C. When the Command option is set to 0 any Final Exit zones included
in Part Set Level C will continue to act as Final Exit zones during Part Set
Level C. When the option is set to 1 any Final Exit zones included in Part Set
Level C will act as Normal Alarm zones during Part Set C.
Level C Entry Route Operation (Command 71)
Command 71 controls how the system treats Entry Route zones during Part
Set Level C. When the option is set to 0 all Entry Route zones included in
Part Set Level C will continue to act as Entry Routes during Part Set Level C.
When the option is set to 1 any Entry Route zones included in Part Set Level
C will act as Final Exit zones during Part Set C.
Level C Exit Mode (Command 72)
Command 72 specifies the exit mode for Level C.
Option 0 The keypad sounders and any internal sounders give a low tone
when entering Part Set Level C. Use Command 75 to select the
exit time.
Option 1 Instant Set (no exit tone)
Option 2 Silent Set. Use Command 75 to program the Exit time. At the end
of the exit time the keypad gives a double beep confirmation tone.
Option 3 Lock Set. See “Level A Exit Mode (Command 39) for an explana-
tion of Lock Set.
Option 4 Level C exit mode is the same as Level A. The system gives full
volume setting tones.
Note that the keypads give a double beep confirmation tone at the end of all
setting modes.
Level C Alarm Response (Command 73)
Command 73 specifies the alarm response for Part Set Level C.
Option 0 Keypad sounders only
Option 1 Internal sounders and keypad sounders
Option 2 Local alarm (internal and external sounder only)
Option 3 Full alarm (communication and internal/external sounders).