22 496792
3. Installation
Once you have connected an expander refer to the instructions supplied in
order to connect detectors.
Once you have connected a 9955 expander then refer to the instructions
supplied in order to "learn" radio detectors to the expander.
Using Programmable Outputs
In the 9751 OP1, 2 and 3 are "pull down type" outputs that provide negative
applied control signals. The system adjusts the output polarity when you
select the output type.
In the 9752 OP 1 and 2 are voltage free relay contacts, while OP3 is the
same type as on the 9751.
To program the outputs use programming command 81 for OP1, command
82 for OP2 and command 83 for OP3 (see "4. Programming").
Figure 15 shows some example applications for OP3.
Shock Sensor Reset
Use Command 83 4
VIPER
+ve
0V
Bell Follow Buzzer/Relay
Use Command 83 0
Relay energises/buzzer sounds
when bell activates.
BUZZER/RELAY
PIR Set Latch/Walk Test
For:
Set Latch use Command 83 3
Walk Test use Command 83 5
PIR
OP3
OP2
OP1
12V
0V
TR
+
LS
12V AUX
0V
12V AUX
0V
OP3
OP2
OP1
12V
0V
TR
+
LS
12V AUX
0V
12V AUX
0V
OP3
OP2
OP1
12V
0V
TR
+
LS
12V AUX
0V
12V AUX
0V
Figure 15. Wiring Examples for Programmable Output OP3
M/C
M/C
M/C
0V
12V
CLK
DATA
ET
PA
SET
RDY
9928
COM
KS2
KS1
Set A
Off
Set B
Set A
Set B
TAMP
Momentary
Continuous
To keypad bus
on control unit.
Figure 16. Connecting a Keyswitch Interface