4. Programming
496792 43
To change: Key-in: Notes Default
Note: The following Commands are available if you select option 1 for Com-
mand 89.
Confirm Timer 160 nnn
nnn is a time in the range 001 to 999 minutes. Default 030 minutes.
Internal Sounder 161 0 Sounder on Unconfirmed Alarm Y
1 Sounder on Confirmed Alarm
External Sounder 162 0 Sounder on Unconfirmed Alarm Y
1 Sounder on Confirmed Alarm
Confirmation After Entry 163 0 Never Y
1 One Zone
2 Two zones
User Reset After 164 0 Disabled Y
Confirmed Alarm 1 Enabled
Leaving Programming Mode
When all programming has been completed:
1. Key-in ‘99 ’ at the keypad
The display shows:
2. Press .
The display shows:
followed by the time and date.
The system is now in user mode.
Note: If there is a fault on the system , for example an open tamper circuit, the
display shows this and will not return to Day mode. Press and rectify the
faults.
Engineer Reset
To perform an Engineer Reset:
1. Check that the display is showing the alarm condition.
2. Key in 0 followed by the Engineer’s code (default 7890), followed by 99 .
The display shows the time and date.
Re-entering Programming Mode
You can go back into programming mode whenever the system is unset and
not in alarm:
1. Key in 0 followed by the Engineer’s code (default 7890).
The display shows:
You are now in programming mode.