4. Programming
38 496792
To change: Key-in: Notes Default
Level C Final Exit 70 0 C=FE = FE (Final exit) Y
1 C=FE = NA (Normal alarm)
Level C Entry Route 71 0 C=ER = ER (Entry route) Y
1 C=ER = FE (Start entry timer)
Level C Exit Mode 72 0 Timed plus low tone Y
1 Instant set
2 Silent set (kpd beeps at end of setting period)
3 Lock set
4 Exit mode same as Level A
Level C Alarm Response 73 0 Keypad Sounder Only
1 Internal Sounder and keypad sounders Y
2 All sounders, no comms
3 Full alarm (comms and sounders)
Level C Entry Time 74 1 10 seconds
2 20 seconds Y
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
Level C Exit Time 75 1 10 Seconds
2 20 seconds Y
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
Level D Exit Mode 76 0 Timed plus low tone Y
(9752 only) 1 Instant set
2 Silent set (kpd beeps at end of setting period)
3 Lock set
4 Exit mode same as Level A
Level D Alarm Response 77 0 Keypad Sounder Only
(9752 only) 1 Internal Sounder and keypad sounders Y
2 All sounders, no comms
3 Full alarm (comms and sounders)
Level D Entry Time 78 1 10 seconds
(9752 only) 2 20 seconds Y
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
Vista de pagina 43