2. Everyday Operation
Page 10 11980075
Timed Set
With Timed Set, the system sets after a programmed exit time has expired.
The time starts when you press a level key, or when you press y to accept an
omitted zone. Your installer will have made the exit time long enough for you
to leave the premises and secure the final door
5
.
When using Terminated Set (see below), your installer may have
programmed the system to set after the exit time even if the exit terminate
button is not pressed. This ensures your premises are protected if you forget
to press the button.
Final Door Set
Your installer may have programmed the system so that closing the final door
completes the setting sequence. The system sets 7–12 seconds
6
after you
secure the final door. There is no fixed exit time.
Lock Set
Your installer may have fitted a special lock so that locking the final door
completes the setting sequence. The lock contains a switch so that the control
unit can sense whether the lock is open or closed. The system sets seven
7
seconds after you lock the final door. There is no fixed exit time.
Note: Lock Set is available only for Level A (Full Set).
Terminated Set
Your installer may have fitted an exit terminate button. This is usually outside,
beside the final door, and you press it when you leave. The system sets
seven
8
seconds after you press the button. There is no fixed exit time.
Silent Set
Some levels on your system may be programmed for Silent Set. The system
does not give an audible warning when it sets these but it gives a double
"beep" at the end of the exit time to show that it is set.
Note: Silent Set is not available for Level A (Full Set).
Instant Set
The area protected by a level may not need an exit route or final door. With
Instant Set, the system sets as soon as you press the appropriate key, without
5
Installer Commands 44, 65, 75 and 79
6
Installer Command 182
7
Installer Command 182
8
Installer Command 182
Vista de pagina 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 27 28

Comentarios a estos manuales

Sin comentarios