Page 26
Note: The internal clock adjusts itself for daylight saving in Spring
and Autumn.
Programming Outputs
During programming the installer may allocate some outputs so
that they can be reprogrammed by an Administrator. This section
describes how the Administrator can use those outputs.
For each output you can, if you wish, set and “on” time and an
“off” time so that the output will go on and off at fixed times each
day. In addition, Master, Admin and Normal users can switch the
output on or off at any time.
To program an output:
1. In the User Menu select System Config - Edit Outputs.
The display shows the Edit Output menu, the bottom line
shows the first in a list of the available outputs.
Note: This option is only visible if the installer has allocated some
outputs to you.
2. Press u or n to select the output you wish to edit then press
>.
The bottom line of the display shows “Name”, the first item
in a menu that allows you to change the name of the
selected output, and to set an “On” and “Off” time for the
output.
3. Press u or n followed by > to select Name to give the
output a meaningful name. (Hint: see Editing Text on page
14.)
The name you give the output appears in all the other menus
the display offers for controlling outputs.
4. Press u or n followed by > to select “On Time” to set a time
when the control unit will switch the output on.
5. Press u or n followed by > to select “Off Time” to set a time
when the control unit will switch the output off. If you do not
wish the output to switch on and off at set time then leave
these two options set to “00:00”.