Cooper Security 9651 Manual de instalación Pagina 79

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 88
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 78
9651 Programming Commands Quick Reference
11772232 Page 75
Command Key in:
1 Delay On
30 PA Response (page 42)
30yny
n =
0 PA response audible
Y
1 PA response silent
31 Zone Tamper User/Engineer Reset
(page 43)
31yny
n =
0 User reset after zone tamper
Y
1 Engineer reset after zone tamper
33 System User/Engineer Reset
(page 43)
33yny
n =
0 User can reset the system
Y
1 Engineer must reset the system
34 PA User/Engineer Reset (page 43)
34yny
n =
0 User reset after PA
Y
1 Engineer reset after PA
35 First Circuit Lockout (page 43)
35yny
n =
0 Lockout first circuit to activate
Y
1 Rearm first circuit to activate
36 Alarm Abort (page 43)
36yny
n =
0 User cannot abort a false alarm
Y
1 User can abort a false alarm
37 Daytime Tamper Communication
(page 44)
37yny
n =
0 Internal sounder only
Y
1 Communicate tamper to ARC
38 System Tamper User/Engineer Reset
(page 44)
38yny
n = 0 User reset after Tamper Alarm
1 Engineer reset after Tamper Alarm
Y
39 Level A Exit Mode (page 44)
39yny
n =
0 Timed (full tone on setting)
Y
1 Terminated (terminated by button)
2 Final Door (last door has a detector)
3 Lock Set (terminated by lock switch)
40 System Auto Rearm (page 45)
40yny
n =
0 Rearm Never
Y
1 Rearm=1 (once)
2 Rearm=2 (twice)
3 Rearm=3 (three times)
4 Rearm=Always
41 Bell Delay (page 46)
41yny
n =
0 No delay
Y
1 1.5 minutes
2 3 minutes
3 5 minutes
4 10 minutes
5 15 minutes
6 20 minutes
42 Bell Duration (page 46)
42yny
n = 1 1.5 minutes
2 3 minutes
3 5 minutes
4 10 minutes
5 15 minutes
Y
6 20 minutes
Command Key in:
44 Level A Exit Time (page 46)
44yny
n = 1 10 seconds
2 20 seconds
Y
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
45 Entry/Exit Tone Volume (page 47)
45yny
n = 0 No Entry/Exit tone from sounder
n EE tone volume (1=low, 9=max)
5
46 Tamper Alarm Response (page 47)
46yny
n = 0 Internal sounders only
1 Keypad sounders only
2 Internal and keypad sounders
Y
48 Lockout Keypads During Entry
(page 47)
48yny
n =
0 Off
Y
1 On
49 Duress Code (page 47)
n =
0 Disabled
Y
1 Enabled
50 CSID Code (page 48)
50ynnnny
nnnn = Central Station ID for remote reset none
51 Set Time and Date (page 48)
51yddy
mmyyyy
hhymmy
dd Day of the month (01–31)
mm Month of the year (01–12)
yy Year (00–99)
hh Hour of the day (01–23)
mm Minute of the hour (01–59)
52 Omit Alarm (page 48)
52yny
n =
0 Alarm contacts only
Y
1 Alarm and tamper contacts
53 Abort User/Engineer Reset (page 49)
53yny
n = 0 Use option selected in Command
33
Y
1 User reset after an aborted alarm
56 Number of Digits in Access Codes
(page 49)
56yny
n =
0 Four-digit codes
Y
1 Six-digit codes
58 Day Tamper User/Engineer Reset
(page 49)
58yny
n =
0 User Reset
Y
1 Installer Reset
59 External Sounder Tamper (page 49)
59yny
n =
0 Negative voltage tamper return
Y
1 End of line 2k2 resistor
60 Level B Final Exit Operation
(page 50)
60yny
n =
0 B=FE = FE (Final Exit)
Y
1 B=FE = NA (Normal Alarm)
61 Level B Entry Route Operation
(page 50)
61yny
n =
0 B=ER = ER (Entry Route)
Y
1 B=ER = FE (Start entry timer)
Vista de pagina 78