i-on160 4. Administration
Page 57
6. Press n until you see:
TEST
Walk Test >
7. Press Y.
The bottom line of the display
shows:
WALK TEST
Chime On
8. Press < or > to turn a chime
tone on or off.
When the chime tone is on, the
keypads and loudspeakers will
sound a chime tone for each
zone that triggers while you
are performing the walk test.
9. Press n. to see the first of the
walk test options:
WALK TEST
System >
The Walk Test menu provides three options to give different ways
of organising a walk test. The options within Walk Test are:
System This option allows you to walk round the entire
system and test all the zones. Press Y to select this
option.
Partitions (Only in partitioned systems.) Use this option to
select one or more partitions, and test the zones
only within those partitions.
Press u or n to scroll up and down the list of
partitions. Press < or > to display “Yes” at the end
of the bottom line to mark the partition as one you
want to test. Press Y when you have finished
making your selection.
Zones This option lets you select one or more individual
zones, and test only those zones and no others.
Press u or n to scroll up and down the list of
zones. Press < or > to display “Yes” at the end of
the bottom line to mark the zone as one you want
to test. Press Y when you have finished making
your selection.