
3. Installation 9752 Installation Guide
Page 18 11976870
Connect the 21VAC lead from the mains transformer to the main PCB. See
Figure 3 for the location of the 21VAC connector.
Caution: Do not apply mains power at this point. Do not work inside the
control unit case when mains power is present.
Keypads
Connecting Keypads
Figure 7 shows the connections for keypads. Use the "ET" connector
terminals on the keypad PCB to connect an exit terminate button or lock
switch. If you are using a lock switch, do not connect any other devices to
these terminals.
9941,9943 Keypad
Figure 7. Keypad Connections
The 9941/9943 keypads can be connected to an external panic attack button,
as shown in Figure 8. If the panic attack does not contain a tamper switch, link
the pair of "EXT TAMPER" terminals. Separately link both pairs of terminals if
no panic button is used.
Figure 8. 9941/9943 Panic Attack Connections
Note: Wired PA switches connected to the keypad work only with software
version 4.03.05 onwards.
Comentarios a estos manuales