3
Options in User Menu 1
Option 1-1: Testing
Option 1-1-1:
Testing the Bell
This option enables you to test the internal
sounder, strobe, external sounder, and
telecommands.
User 1 Menu 1
Test Menu
1. Press [ to select this option.
Test Menu 1
Bell Test
2. Press [ to select Bell Test.
Bell test wards:
Ward > 1*......
3. Use the number keys to select the
wards, then press [. Any ward shown
will be tested. (A “*” means that the
ward will not be tested. A “.” means that
either you have no access, or the ward
is not programmed.)
Bell Test 1
Bell Only
4. The external sounder should activate.
Press [ to carry out the next test.
Bell Test 2
Bell & Strobe ON
5. The external sounder and strobe should
be active. Press [ to carry out the next
test.
Bell Test 3
Strobe Only
6. Only the strobe should be active. Press
[ to carry out the next test.
Bell Test 4
Alarm Sounder On
7. The internal sounder should activate.
Press [ to carry out the next test.
Bell Test 0
Bell/Strobe OFF
8. The sounders and strobe should switch off.
Press [ to repeat the tests, or ] to exit.