5 Appendix B Specification
Ethernet Interface
10Mbps and 100Mbps (10/100BaseT) with auto-negotiation
UTP with standard RJ45 socket for CAT-5 cabling
Dynamic IP addressing (DHCP) or fixed
GSM/GPRS Interface
Dual band GSM 900 MHz and DCS 1800 MHz
SMA socket for antenna connection
IP
TCP ports (outbound): 51292 (diagnostics), 52737 (polling), 53165 (alarms), 10001 (Upload/Download).
PIN Inputs
Maximum input voltage range
0V to +30V
Input ‘low’ threshold
< 2V
Input ‘high’ threshold
> 3V
Input pull-up impedance
Internal 10K to 3.3V supply
Relay Outputs
Maximum operating voltage
30V
Maximum current rating
100mA
Power Supply
Supply voltage
9 - 30V DC
Typical Current (supply at 12v)
T620: 120mA T640: 155mA
Max Current (supply at 12v)
T620: 145mA T640: 185mA
Note: These figures are based upon the Ethernet link being connected. With GSM/GPRS there will also be
additional transient peak current of up to 250mA required as GSM and GPRS transmissions (e.g. for network
registration and calls) are made.
Weights
Dialer unit
T620: 70g T640: 75g
6 Conformance
The IRIS Touch range comply with the following Standards:
72/23/EEC Low Voltage Directive
89/336/EEC & 92/31/EEC EMC Directive
EN50136-1-1 Alarm transmission
EN50131-1 Intruder systems
The IRIS diallers conform to Environmental Class II.
The IRIS diallers are compliant to ATS 6 compatible with Security Grade 4.
The IRIS Touch Range is suitable for use in systems complying to these standards.