Appendix A 7510r
Page 78
Unsetting (Clause 6.4)
The table below summarises which options to use within
System Options, Alarm Confirmation to ensure compliance
with DD243: 2004 paragraphs 6.4.2, 6.4.4 or 6.4.5.
DD243: 2004 Para: 6.4.2 6.4.4 6.4.5
Possible Installation
System Options Menu
Item:
Unset from
outside the
premises using a
keyswitch zone
input – entry must
be prevented
until system is
unset
Keypad and user
access code
Portable ancillary
control equipment –
with the reader inside
the premises
Confirmation Used DD243
Entry Code Lockout No No Yes
After Entry Never Never Two zones
Note: When you enable Alarm Confirmation the control
unit sets the confirm time to 30 minutes.
Homelink 75 cannot comply with DD243: 2004
paragraphs 6.4.3 or 6.4.6.
Sounders and Status Indication
Once you have enabled alarm confirmation, then the
following menu options provide further facilities that may
be useful in a DD243:2004 installation.
Command Name Value Notes
Outputs Type
Alarm Conf,
Setting
Complete
Use these two output types to
indicate the status of the
system.
System Options Panel Siren
No Use this option to disable the
control unit siren.
System Options,
Alarm Confirmation
External
Sounder for
Any Use this option to determine if
the external sounder
responds to confirmed or
unconfirmed alarms.