Programming Reference - Detectors 7510r
Page 22
Exit Normal Alarm
A zone programmed as ‘Exit Normal Alarm’ behaves
similarly to a Normal Alarm zone. However, a zone of
this type will start an alarm if the detector is
triggered during the exit time.
Partitions and Zones
When you first teach a detector to the control unit then
the zone defaults to partition 1.
You can assign zones of the following type to one or more
partitions: Normal Alarm, Final Exit, Entry Route, Key
Box, and Exit Normal Alarm.
Note: If you intend to use part set partitions then make
sure that for any zone shared by more than one
partition the part set options are all the same.
The control unit will not allow you to assign zones of the
following types to more than one partition: 24 Hour, Fire,
Panic Alarm, and Technical.
Zone Attributes
The attributes available are:
Chime
When enabled by the user, the system gives a non-
alarm warning tone when any zones programmed as
‘Chime’ are opened. This facility operates only while
the system is unset.
Soak Test
Use this zone attribute if you want to place under
long term test a detector that you suspect is giving
false alarms. Zones with this attribute are disabled
for 14 days after you return the control unit to user
mode. If the zone is activated while the system is set
then the control unit logs the event as a “Soak Test
Fail Zn” (n is the zone number) without sounding any
sirens or starting signalling. After midnight on the
14th day the control unit returns the zone to normal
use.
Activity Monitoring
While a partition holding a zone with this attribute is
unset, the control unit starts a Social Care Alarm if
the detector has not been activated for a set time.