Programming Reference - Reporting 7510r
Page 56
With CID the control unit sends only the last four digits of
the account code.
With Fast Format you can use four-, five- or six-digit
codes. The control unit pads five-digit codes to six digits
using a leading zero. The control unit leaves four- and
six-digit codes unchanged.
Note: If you need to add a letter to the account code
press the numbers keys repeatedly until the letter
you want appears on the display. See page 19.
Report Type
To choose the report type to send to the ARC select:
Reporting, Alarms, Report Type.
The report types available are: Fast Format, Contact ID,
SIA Level I, SIA Level II, SIA Level III and Extended SIA
Level III, and CID in SMS.
Note: If you select “CID in SMS” then you must store the
phone number of the ARC in
Reporting, Alarms, Phone
Book
.
Fast Format Channels
If you selected Fast Format in Report Type then you can
select Reporting, Alarms, Fast Format Channel to allocate
one of the following events to each of the 8 channels
(defaults in brackets):
Not used
Fire (default Channel 1)
PA (defaulted Channel 2)
Burglar (defaulted Channel 3)
Open/Close (default Channel 4)
Technical Alarm (default Channel 8)
RF Low Battery
Supervision Loss
RF Jamming
AC Fail
Tamper Alarm
Medical
Open (see note 1)