ALARM #### Alarm from zone number ####
ALARM WARDS:- Alarm in wards
AUTOSET # OFF Autoset timer off
AUTOSET # ON Autoset timer on
AUXILIARY #### Technical alarm from zone number ####
AUXILIARY # TAMP Auxiliary 1 or 2 tamper
AUXILIARY FUSE Auxiliary Fuse failed
BATTERY FAULT Battery disconnected or voltage level below 9.5V
BATTERY RESTORE Battery restored to healthy condition
BEAM PAIR #### First activation of a beam pair zone number ####
BELL BOX TAMPER External sounder/bell tamper
BELL TESTED:- Bell tested for wards
BELLS ACTIVE:- Bell active for wards
CALL ABORTED Remote service call aborted
CALLED No. # Remote service call initiated via panel to remote PC 1, 2 or
3
CALLING BACK No. # Remote service call requested via PC to “Call back No” 1, 2
or 3
CCT ON TEST #### Zone number #### put on test
CCT TESTED #### Zone number #### tested during walk test routine
CCTS REINSTATED Zones reinstated with a shunt code
ZONES SHUNTED Zones shunted with a shunt code
CODE LOCK # OFF Code lock number # is off
CODE LOCK # ON Code lock number # is on
CODE LOCKED ### User number ### attempted to use their code while
locked-out
CODE TAMPER Keypad locked out for 5 minutes due to invalid entry of
code
COMMS FAILED Plug-on digicom failed to communicate with ARC
COMMS SUCCESSFUL Plug-on digicom communicated successfully with the ARC
DATE CHANGED System date changed
DEFAULT USER ### User 001 defaulted to 5678
DEFERRED SET:- Deferred set on wards
DIGI-COM FITTED Plug-on digicom fitted
DIGI/MODEM LOST Plug-on digicom or modem removed
DIGI/MODEM RESET Plug-on digi-modem reset
DURESS CODE ### Duress alarm from user number ###