the user to appear to operate the alarm
system normally if being coerced.

To set up a Duress code, the Duress
Allow setting in Engineer option 1-9-1
must be set to YES.
Access
AccessAccess
Access
Users of this type have no access to user
menus and cannot set or unset the system.
Entering a user code of this type temporarily
activates outputs of type "Code Accepted"
or "Access Code", which could be used to
operate electric door strikes or similar
mechanisms.
Shunt
ShuntShunt
Shunt
Users of this type have no access to user
menus and cannot set or unset the system.
Entering a user code of this type isolates the
zones in the shunt group(s) to which it is
assigned. Entering the code again
reinstates the zones. See page 17 for
details of shunt groups.
Set Only
Set OnlySet Only
Set Only
Users of this type have no access to user
menus. They can set assigned wards but
cannot unset them.
Not in use
Not in useNot in use
Not in use
This user type has no rights. Select this type
to delete an existing user.
Option 2-4-1:
Configuring the User
Codes
This option enables you to set up or modify
users. For each user, you specify
information such as the user type and the
wards the user has access to.
User 2 Menu 4
Edit Codes
1. Press [ to select this option.