7
Option 1-3: Shunting 24hr Zones
This option enables you to shunt (disable) all
zones in selected wards that have been set
up as shuntable in Engineer option 1-1.
Shunting disables a zone and the shuntable
attribute identifies whether this is permissible.
This is normally used for 24-hour zones
but can be applied to other zone types.
Zones remain shunted until you use the
Reinstate 24hr option (see below).
Reinstating zones may start the exit timer,
depending on whether Unshunt, No Exit
or Unshunt & Exit is selected (Engineer
option 1-9-1).
User 1 Menu 3
Shunt 24hr Zones
1. Press [ to select this option.
1=Shunt 24hr
2=Reinstate 24hr
2. Press 1 to shunt zones or 2 to reinstate
zones that have been previously
shunted.
Shunt wards
Ward > 1*......
3. Use the numeric keys to select the wards
to shunt/reinstate, then press [. Any
ward numbers shown will be
shunted/reinstated. (A “*” indicates that
the ward will not be shunted/reinstated,
and “.” Indicates that you have no
access to the ward.)